5.4.7.

Read the PICC Operating Parameter

This command is used to check current PICC operating parameter.

Read the PICC Operating Parameter Format (5 Bytes)

Command

Class

INS

P1

P2

Lc

Read the PICC

Operating Parameter

0xE0h

0x00h

0x00h 0x20h

0x00h


Read the PICC Operating Parameter Response Format (6 Bytes)

Response

Class

INS

P1

P2

Le

Data Out

Result

0xE1h

0x00h

0x00h

0x00h

0x01h

Operation

Parameter


Operating Parameter (1 Byte)

Operating

Parameter

Parameter

Description

Option

Bit0

ISO 14443 Type A

The Tag Types to be

detected during PICC Polling.

1 = Detect
0 = Skip

Bit1

ISO 14443 Type B

1 = Detect
0 = Skip

Bit2 - 7

RFU

RFU

RFU