Set the picc operating parameter – ACS ACR1283L User Manual
Page 37

ACR1283L – Reference Manual
Version 1.00
www.acs.com.hk
Page 37 of 55
5.4.6.
Set the PICC Operating Parameter
This command is used to set the PICC operating parameter.
Set the PICC Operating Parameter Format (6 Bytes)
Command
Class
INS
P1
P2
Lc
Data In
Set the PICC
Operating Parameter
0xE0h
0x00h
0x00h 0x20h
0x01h
Operation
Parameter
Set the PICC Operating Parameter Response Format (6 Bytes)
Response
Class
INS
P1
P2
Le
Data Out
Result
0xE1h
0x00h
0x00h
0x00h
0x01h
Operation
Parameter
Operating Parameter (1 Byte)
Operating
Parameter
Parameter
Description
Option
Bit0
ISO 14443 Type A
The Tag Types to be
detected during PICC Polling.
1 = Detect
0 = Skip
Bit1
ISO 14443 Type B
1 = Detect
0 = Skip
Bit2 - 7
RFU
RFU
RFU
Note: Default value of Operation Parameter = 0x03h