Chart 1 troubleshooting – RIDGID SeeSnake LT1000 User Manual
Page 20
SeeSnake® LT1000
18
PROBLEM
PROBABLE FAULT LOCATION
SOLUTION
Camera video image not
seen.
No power to SeeSnake.
Check power is correctly plugged in or bat-
tery is charged.
Check Power Key on LT1000 by pressing.
Connections faulty.
Check connection to LT1000 unit from
SeeSnake.
Batteries Low.
Check seating and pin condition in the Se-
eSnake System connection. Clean if need-
ed.
Recharge batteries or connect external pow-
er supply.
Flashing Battery Warning
appears.
LT1000 18V batteries low.
Recharge LT1000 batteries. Switch to AC pow-
er (110 - 240V AC).
LT1000 video freezes.
Low-quality AC power or voltage spike.
Power cycle the LT1000 OFF and then ON.
No video.
If your computer doesn’t recognize the
USB connection.
Restart your computer, power cycle LT1000
or close HQ and restart it to see if this cor-
rects the problem.
Do not start your computer with the LT1000
turned ON.
The LT1000 should be turned OFF, though
it’s ok to have the USB cable plugged in.
NOTE: The USB connector (See Figure 12)
on the LT1000 was designed to be a water-
resistant seal, so it is a tight fit. Your LT1000
was tested and shipped with this cable
firmly connected. If you need to disconnect
and reconnect this cable (for example, if you
break your USB cable), make sure you push
the connector in all the way. If you don’t,
the HQ software might not recognize the
LT1000. If so, make sure you have pushed
the connector in all the way. You may have
to restart HQ to recognize the connection.
Chart 1 Troubleshooting