beautypg.com

2 switch access and login, Switch access and login – ZyXEL Communications ES-3148 Series User Manual

Page 284

background image

Chapter 37 Troubleshooting

ES-3148 User’s Guide

284

37.2 Switch Access and Login

V

I forgot the IP address for the Switch.

1 The default out-of-band management IP address is 192.168.0.1. The default in-band

management IP address is 192.168.1.1.

2 Use the console port to log in to the Switch.
3 Use the management port to log in to the Switch. Use the out-of-band management IP

address.

4 If this does not work, you have to reset the Switch to its factory defaults. See

Section 4.6

on page 59

.

V

I forgot the user name or password.

1 The default user name is admin, and the default password is 1234. These fields are case-

sensitive, so make sure [Caps Lock] is not on.

2 If this does not work, you have to reset the Switch to its factory defaults. See

Section 4.6

on page 59

.

V

I cannot see or access the Login screen in the web configurator.

1 Make sure you are using the correct IP address.

• The default out-of-band management IP address is

192.168.0.1

.

• The default in-band management IP address is

192.168.1.1

.

• If you changed the IP address (

Section 7.6 on page 79

), use the new IP address.

• If you changed the IP address and have forgotten it, see the troubleshooting

suggestions for

I forgot the IP address for the Switch.

2 Check the hardware connections, and make sure the LEDs are behaving as expected. See

Section 3.3 on page 47

.

3 Make sure your Internet browser does not block pop-up windows and has JavaScripts

and Java enabled. See

Appendix B on page 317

.

4 Make sure your computer is in the same subnet as the Switch. (If you know that there are

routers between your computer and the Switch, skip this step.)

5 Try to access the Switch using another service, such as Telnet. If you can access the

Switch, check the remote management and secure client settings to find out why the
Switch does not respond to HTTP.

6 Reset the Switch to its factory defaults, and try to access the Switch with the default IP

address. See