C Command - Counter
Description The counter (
C
) command defines one of 10
automatic counters used in consecutive num-
bering applications (i.e. serial numbers). Coun-
ters must be defined after variables.
For Numeric Serialization Only. The counter
function does not support Alpha or Alpha-Numeric
Serialization.
Syntax
Cp
1
,
p
2
,
p
3
,
p
4
, “
[-]PROMPT
”
Parameters
p
1
= Counter number. Range:
0
to
9
p
2
= Maximum number of digits for the counter.
Range:
1
to
29
p
3
= Field Justification.
L
= Left
R
= Right
C
= Center
N
= No Justification
p
4
= Step Value.
+
or
-
sign followed by a
single digit of
1 - 9
. Using a step value of
+0
allows the counter to be used as an
additional variable data field.
“
PROMPT
”= An ASCII text field that will be
transmitted to the KDU or host (via the
serial interface) each time the command
is executed. Typically used to request the
operator to enter a starting counter value.
KDU Prompt
Options
[
-
] = Having the first character of the prompt
a single minus sign will cause the
prompt to display only once after form
retrieval.
980352-001 Rev.A