Tt - define time layout 3-89, Command - define time layout -89 – Zebra Technologies EPL2 User Manual
Page 107

TT Command - Define Time Layout
Description Use this command to define the time format
when printing.
Syntax
TTp
1
[|p
2
|p
3
][+]
Parameters
P
1
,
P
2
,
P
3
=
h, m,
or
s
These parameters describe the format of
the time display.
·
At lease one parameter must be supplied.
·
Each parameter can be any of the values
h
,
m
, or
s
and are described below.
Value
Description
h
Hours displayed as 2 digits (e.g. 01)
m
Minutes displayed as 2 digits (e.g. 15)
s
Seconds displayed as 2 digits (e.g. 00)
[+]
=
Enable 12 Hour clock format
Appending a + to the end of the com-
mand string selects 12 hour clock mode.
The times will display with an “AM” or
“PM” indicator.
Default
(no
+
) =
24
hour clock mode
|
= Separator character
The separator may be any ASCII char-
acter value between 032 and 063. The
separator character is printed between
the results of each of the supplied pa-
rameters.
This command works only in printers equipped with
the Real Time Clock time and date option.
Examples: If the current time is 1:25 p.m.:
TTh:m:s+↵
: 01:25:00
TTh,m↵
: 13,25
TTh+↵
: 01 PM
980352-001 Rev.A
3-89