beautypg.com

Table 18 u interface connector specification, Procedure 23, Connecting the isdn bri terminals to the dsl – Nortel Networks NN43001-318 User Manual

Page 76: Procedure

background image

76

Configuring ISDN BRI hardware

Note 1: Power Source 1 (PS1): Up to 2 Watts of power is supplied by
the SILC to the terminals on the DSL. This power is simplexed over the
TX and RX pairs provided by -48 V (-40 V for Europe) supply on the
SILC. The RX pair is positive with respect to the TX pair.

Note 2: Power Sink 2 (PS2) provides an optional means of powering
the terminal from a common supply in the wiring closet.

Note 3: Power Source 3 (PS3) provides the power from the terminal to
the NT1 if the NT1 does not have a local power source.

U interface specification

The U interface uses a 2-conductor, twisted pair cable terminated with
an RJ-45 type jack. An RJ-45 type jack on the NT1 device connects the
terminal to the DSL using this twisted pair cable.

The connector pin assignments for the jack and the plug are shown in

Table

18 "U interface connector specification" (page 76)

. The table also shows

signal names for each interface pin at the UILC and at the terminal.

Table 18
U interface connector specification

Pin number

RJ45 jack
pin signal name

UILC
signal name

1

Not used

No connection

2

Not used

No connection

3

Not used

No connection

4

Tip or Ring

Tip or Ring

5

Tip or Ring

Tip or Ring

6

Not used

No connection

7

Not used

No connection

8

Not used

No connection

Procedure 23

Connecting the ISDN BRI terminals to the DSL

Step

Action

1

Plug one end of the modular cable into the ISDN BRI interface
connector on the terminal. Plug the other end of the modular cable
into the telephone outlet.

2

If the SILC S/T interface has an optional auxiliary power source,
plug the power source into the wall outlet and then the 10-m (33-ft)
modular cable into the power source’s RJ-45 type jack.

Nortel Communication Server 1000

ISDN Basic Rate Interface Installation and Commissioning

NN43001-318

01.02

Standard

Release 5.0

20 June 2007

Copyright © 2003-2007, Nortel Networks

.