beautypg.com

Nortel Networks NN43001-318 User Manual

Page 47

background image

47

Preparing the system

Contents

This section contains information on the following topics:

"Introduction" (page 47)

"Verifying ISDN BRI operation" (page 47)

"Setting up ISDN BRI test terminals and trunks" (page 48)

Introduction

This chapter describes how to prepare ISDN BRI equipment for acceptance
testing. It explains how to verify that ISDN BRI cards are enabled and
functioning correctly and how to correct any problems before starting the
test.

Verifying ISDN BRI operation

After ISDN BRI equipment has been installed and configured, you can
visually inspect ISDN BRI cards to make sure that they are operating
correctly by observing their LEDs:

Check the red Dis LED located on the MISP faceplate. If the Dis LED
on an MISP is lit, check that the MISP is disabled or faulty. If it is
extinguished, check that the MISP is enabled and operating. To enable
the MISP or to correct a problem, refer to ISDN Basic Rate Interface
Maintenance (NN43001-718)
.

Check the red LED located on the BRSC faceplate. If the red LED is
extinguished, check that the BRSC is enabled and operating correctly. If
the red LED is lit, check that the BRSC is manually disabled or faulty.
To enable a BRSC or to correct a problem, refer to ISDN Basic Rate
Interface Maintenance (NN43001-718)
.

Check the red LED located on the SILC and UILC faceplates. If the
red LED is extinguished, check that the SILC or UILC is enabled and
operating correctly. If the red LED is lit, check that the SILC or UILC
is manually disabled or faulty. To enable an SILC or a UILC or to

Nortel Communication Server 1000

ISDN Basic Rate Interface Installation and Commissioning

NN43001-318

01.02

Standard

Release 5.0

20 June 2007

Copyright © 2003-2007, Nortel Networks

.