Nortel Networks NN43001-318 User Manual
Page 71
Installation procedures
71
Table 16 "SILC and UILC port assignments connectors at cross-connect
terminal" (page 71)
identifies SILC and UILC port assignments connectors
at the cross-connect terminal.
Table 16
SILC and UILC port assignments connectors at cross-connect terminal
SILC port
signals
UILC port
signals
Connector
pin number
and wire
color code
Wire
color
codes
Card ports
0 TX-
0 T
26
W-BL
0 TX+
0 R
1
BL-W
0 RX-
27
W-O
Port 0
0 RX+
2
O-W
1 TX-
1 T
28
W-G
1 TX+
1 R
3
G-W
1 RX-
29
W-BR
Port 1
1 RX+
4
BR-W
2 TX-
2 T
30
W-S
2 X+
2 R
5
S-W
2 RX-
31
R-BL
Port 2
2 RX+
6
BL-R
3 TX-
3 T
32
R-O
3 TX+
3 R
7
O-R
3 RX-
33
R-G
Port 3
3 RX+
8
G-R
4 TX-
4 T
34
R-BR
4 TX+
4 R
9
BR-R
4 RX-
35
R-S
Port 4
4 RX+
10
S-R
5 TX-
5 T
36
BK-BL
5TX+
5 R
11
BL-BK
5RX-
37
BK-O
Port 5
5RX+
12
O-BK
Note: The cable pair designated TX- TX+ is the transmit pair and the pair
designated RX+ RX- is the receive pair of the S/T interface. The cable pair
designated T R is the Tip and Ring of the 2B1Q full-duplex U interface.
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318
01.02
Standard
Release 5.0
20 June 2007
Copyright © 2003-2007, Nortel Networks
.