Nortel Networks NN43001-318 User Manual
Page 67
Installation procedures
67
and
Figure 21 "Cable connectors in the
on
Figure 20 "Cable connectors in
, and
Figure 22 "Cable connectors in the
second expansion cabinet" (page 69)
2
Connect an NE-A25B cable to each connector associated with a
card slot containing a SILC or UILC circuit card. See
"Cable connectors in main cabinet" (page 68)
and
connectors in the expansion cabinet" (page 68)
on
connectors in the expansion cabinet" (page 68)
and
connectors in the second expansion cabinet" (page 69)
and
23 "Back of MG 1000S cable connectors" (page 69)
on
"Back of MG 1000S cable connectors" (page 69)
.
Tag both ends of each cable with the cabinet or MG 1000S connector
numbers.
3
Connect the cables to the connectors at the bottom of the cabinet
or at the rear of the MG 1000S.
4
Replace the retaining bar when you connect all the cables to the
system.
5
Terminate the 25-pair cables at the cross-connect terminal.
6
Label the cross-connect terminal for each connector (UILC or SILC).
Figure 24 "SILC port designation label at the cross-connect
terminal" (page 69)
and
Figure 25 "UILC port designation label
at the cross-connect terminal" (page 70)
on
designation label at the cross-connect terminal" (page 70)
show the
label used with the BIX cross-connecting system.
Note: Use of the BIX cross-connect system is not mandatory.
The system supports other cross-connect equipment. Refer to
the documentation provided with your cross-connect system for
further information.
—End—
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318
01.02
Standard
Release 5.0
20 June 2007
Copyright © 2003-2007, Nortel Networks
.