beautypg.com

Procedure 15 installing the misp, Procedure 15, Installing the misp – Nortel Networks NN43001-318 User Manual

Page 59

background image

Installation procedures

59

ISDN BRI Card

MISP

(see Note 2)

SILC is not

clock reference

SILC is cloc

k reference

UILC

Call Server

1-4

1-4

1-4

1-4

MG 1000S 1

11-14

11-14

11-14

11-14

MG 1000S 2

21-24

21-24

21-24

21-24

MG 1000S 3

31-34

31-34

31-34

31-34

MG 1000S 4

41-44

41-44

41-44

41-44

Expansion 1

17-20

17-20

17-20

Expansion 2

27-30

27-30

27-30

Expansion 3

37-40

37-40

37-40

CS 100
0S, CS
1000M,
OPtion
11C
Chassis

Expansion 4

Not

applicable

47-50

47-50

47-50

Note 1: For CS 1000S, physical card slots are numbered 1-4 on each MG 1000S, and 7-10 on
each MG 1000S Expansion.

Note 2: One MISP chassis supports a set of four SILCs or UILCS, or a combination of SILCs
and UILCs.

Procedure 15

Installing the MISP

Step

Action

1

Remove the cover from the system.

ATTENTION

IMPORTANT!

Wear the static discharge bracelet located inside the system before
handling circuit cards. Failure to wear the bracelet can damage the circuit
cards.

2

Remove the MISP from its shipping package and hold it by its
card-locking devices.

3

Insert the MISP into the selected card slot and lock it in place.

4

Observe the behavior of the LED on the faceplate of the MISP to
determine its status:

The LED lights, flashes three times and then stays lit – the MISP
is operating correctly but is not configured and enabled.

Nortel Communication Server 1000

ISDN Basic Rate Interface Installation and Commissioning

NN43001-318

01.02

Standard

Release 5.0

20 June 2007

Copyright © 2003-2007, Nortel Networks

.