beautypg.com

Table 17 s/t interface connector specification – Nortel Networks NN43001-318 User Manual

Page 75

background image

Installation procedures

75

Connecting the ISDN BRI terminals

ISDN BRI terminals are connected

to DSLs using modular cables not longer than 10 m (33 ft) with RJ-45 type
plugs on each end. One end of the cable is plugged into the terminal, and
the other end is plugged into the telephone outlet.

All terminals must be compatible with the system and comply with one of
the following protocols for ISDN BRI terminals:

ETSI NET-3

INS NET-64

NUMERIS

ANSI standards

Contact your Nortel Networks representative for the latest list of compatible
terminals.

To connect 1TR6 terminals, an ETSI NET-3 to 1TR6 protocol converter
is required. A terminal adapter (the So-Adapter) has been specifically
designed to interface with the ISDN BRI DSL and the 1TR6 terminals. Its
main function is to convert 1TR6 protocol, sent from the 1TR6 terminal into
the ETSI NET-3 protocol required for ISDN BRI.

S/T interface specification

The S/T interface uses an 8-conductor modular cable terminated with an
8-pin RJ-45 type plug. An 8-pin RJ-45 type jack located on the terminal
connects the terminal to the DSL using this modular cable.

Table 17 "S/T interface connector specification" (page 75)

shows the

connector pin assignment for the jack and the plug. It also shows the signal
names for each interface pin at the SILC and at the terminal.

Table 17
S/T interface connector specification

Pin number

RJ45 jack
pin signal name

SILC
signal name

1

Power Source 3

No connection

2

Power Source 3

No connection

3

TX +

RX +

4

RX +

TX +

5

RX -

TX -

6

TX -

RX -

7

Power Sink 2 (-)

No connection

8

Power Sink 2 (+)

No connection

Nortel Communication Server 1000

ISDN Basic Rate Interface Installation and Commissioning

NN43001-318

01.02

Standard

Release 5.0

20 June 2007

Copyright © 2003-2007, Nortel Networks

.