Nortel Networks 8005DC User Manual
Page 92
92
Installing Metro Ethernet Routing Switch 8600 modules and connecting equipment
Module
Port
Connector
Recommended
cable type
Minimum
cable
length
Maximum
cable
length
OC-3
MT-RJ
9/125 µm
single-mode
fiber-optic cable
None
9.3 mi
(15 km)
8683POSM
OC-3
OC-3
MT-RJ
62.5/125 µm
multimode
fiber-optic cable
None
1.24 mi
(2 km)
OC-12
Duplex SC
9/125-µm
single-mode
fiber-optic cable
None
9.3 mi
(15 km)
8683POSM
OC-12
OC-12
Duplex SC
62.5/125 µm
multimode
fiber-optic cable
None
1640 ft
(500 m)
8683XLR
10GBase-
LR port
Duplex LC
See Note 5
None
See Note 5
8683XZR
10GBaseR
port
Duplex LC
See Note 5
None
See Note 5
Ethernet
Manage-
ment port
RJ-45
EIA Category 3,
4, or 5 UTP for
10 Mb/s operation;
EIA Category 5
UTP required
for 100 Mb/s
operation
8691omSF
Serial ports
DB-9
RS-232
None
328 ft
(100 m)
Ethernet
Manage-
ment port
RJ-45
EIA Category 3,
4, or 5 UTP for
10 Mb/s operation;
EIA Category 5
UTP required
for 100 Mb/s
operation
8692omSF
Serial ports
DB-9
RS-232
None
328 ft
(100 m)
Note 1: Ports on the 8632TXE, 8632TXM, 8648TXE, and 8648TXM modules are wired as MDI-X.
Use straight-through cables to connect these ports to MDI connections such as workstations or
servers. Use crossover cables to connect these ports to other MDI-X connections such as hubs or
other switches.
Note 2: Depends on installed GBIC model; for specifications, see Nortel Installation — SFP, XFP,
and GBIC Hardware Components (NN46225-301).
Note 3: Depends on installed SFP model; for specifications, see Nortel Installation — SFP, XFP,
and GBIC Hardware Components (NN46225-301).
Nortel Metro Ethernet Routing Switch 8600
Installation — Modules
NN46220-306
02.02
Standard
4.2
7 July 2008
Copyright © 2005-2007, Nortel Networks
.