Triggers, Digital trigger, Bus interface – National Instruments Low-Cost Multifunction I/O Board for ISA Lab-PC+ User Manual
Page 87: Power requirements (from pc), Physical, Environment

Specifications
Appendix A
Lab-PC+ User Manual
A-6
© National Instruments Corporation
Digital logic levels ........................................
Level
Min
Max
Input low voltage
Input high voltage
-0.3 V
2.2 V
0.8 V
5.3 V
Output low voltage
(I
out
= 4 mA)
Output high voltage
(I
out
= -1 mA)
-
3.7 V
0.45 V
-
Triggers
Digital Trigger
Compatibility ..........................................
TTL
Response .................................................
Rising
edge
Pulse width ..............................................
250
ns
Bus Interface
....................................
Slave
Power Requirements (from PC)
+5 VDC (
±
10%) ............................................
180
mA
+12 VDC .......................................................
80 mA
-12 VDC ........................................................
450
mA
Power available on rear connector ................
+5 V at 1 A max
Physical
Dimensions....................................................
16.5 by 9.9 cm. (6.5 by 3.9 in)
I/O connector.................................................
50-pin
male
Environment
Operating temperature...................................
0
°
to 70
°
C
Storage temperature ......................................
-55
°
to 150
°
C
Relative humidity ..........................................
5% to 90% noncondensing