Chapter 2

Configuration and Installation

© National Instruments Corporation

2-3

Lab-PC+ User Manual

Table 2-1. PC Bus Interface Factory Settings

Lab-PC+ Board

Default Settings

Hardware Implementation

Base I/O Address

Hex 260

A5

1 2 3 4 5

O
N

O
F
F

U1

A9

A8

A7

A6

DMA Channel

DMA Channel 3
(factory setting)

W6: DRQ3,

DACK*3

Interrupt Level

Interrupt level 5 selected
(factory setting)

W5: Row 5

Note: The shaded portion indicates the side of the switch that is pressed down.

Base I/O Address Selection

The base I/O address for the Lab-PC+ is determined by the switches at position U1 (see
Figure 2-1). The switches are set at the factory for the base I/O address hex 260. This factory
setting is used as the default base I/O address value by National Instruments software packages
for use with the Lab-PC+. The Lab-PC+ uses the base I/O address space hex 260 through 27F
with the factory setting.

Note: Verify that this space is not already used by other equipment installed in your

computer. If any equipment in your computer uses this base I/O address space, you
must change the base I/O address of the Lab-PC+ or of the other device. If you change
the Lab-PC+ base I/O address, you must make a corresponding change to any software
packages you use with the Lab-PC+. For more information about your computer’s
I/O, refer to your computer’s technical reference manual.

Each switch in U1 corresponds to one of the address lines A9 through A5. Press the side marked
OFF to select a binary value of 1 for the corresponding address bit. Press the other side of the
switch to select a binary value of 0 for the corresponding address bit. Figure 2-2 shows two
possible switch settings.