Mode 1 input timing – National Instruments Low-Cost Multifunction I/O Board for ISA Lab-PC+ User Manual
Page 49
Signal Connections
Chapter 3
Lab-PC+ User Manual
3-18
© National Instruments Corporation
Mode 1 Input Timing
The timing specifications for an input transfer in Mode 1 are as follows:
DATA
RD *
INTR
IBF
STB *
T1
T2
T4
T7
T6
T3
T5
Name
Description
Minimum
Maximum
T1
STB* pulse width
500
–
T2
STB* = 0 to IBF = 1
–
300
T3
Data before STB* = 1
0
–
T4
STB* = 1 to INTR = 1
–
300
T5
Data after STB* = 1
180
–
T6
RD* = 0 to INTR = 0
–
400
T7
RD* = 1 to IBF = 0
–
300
All timing values are in nanoseconds.
See also other documents in the category National Instruments Computer Accessories:
- R Series Intelligent DAQ PXI-784xR (14 pages)
- 7344 (66 pages)
- Relay Module SCC-RLY01 (9 pages)
- Compact FieldPoint Mounting Accessories cFP-21xx (10 pages)
- PCI-4451 (115 pages)
- NI 6239 (172 pages)
- SCXI-1190 (54 pages)
- SCXI-1190/1191 (45 pages)
- NI 785xR (74 pages)
- DIO 6533 (125 pages)
- Multisystem eXtension Interface NI PCIe-836x (37 pages)
- GPIB-BUF (40 pages)
- 6527 (47 pages)
- PCI-8336 (43 pages)
- PXI NI PXI-8105 (73 pages)
- 6025E (136 pages)
- NI 78xxR (12 pages)
- PCI-6110E/6111E (113 pages)
- NI 6115/6120 (127 pages)
- 1128 (97 pages)
- 800 Series (104 pages)
- NI 6115 (127 pages)
- NI 784xR (74 pages)
- GPIB-100A (43 pages)
- VXI-MIO Series (151 pages)
- PC-DIO-24/PnP (107 pages)
- PC-LPM-16/PnP (125 pages)
- NI 7831R (71 pages)
- 653X (147 pages)
- VXI/VME 600 (61 pages)
- PXI NI PXI-1052 (70 pages)
- PC-DIO-96 (105 pages)
- NI UES-3880 (14 pages)
- GPIB-COM (56 pages)
- Switch Executive (8 pages)
- AT-MIO-16X (330 pages)
- 7340 PCI (67 pages)
- NI 783xR (73 pages)
- NI CVS-1450 Series (91 pages)
- SCXI-1321 (16 pages)