Mode 1 Input Timing

The timing specifications for an input transfer in Mode 1 are as follows:

DATA

RD *

INTR

IBF

STB *

T1

T2

T4

T7

T6

T3

T5

Name

Description

Minimum

Maximum

T1

STB* pulse width

500

T2

STB* = 0 to IBF = 1

300

T3

Data before STB* = 1

0

T4

STB* = 1 to INTR = 1

300

T5

Data after STB* = 1

180

T6

RD* = 0 to INTR = 0

400

T7

RD* = 1 to IBF = 0

300