beautypg.com

Mode 1 output timing – National Instruments Low-Cost Multifunction I/O Board for ISA Lab-PC+ User Manual

Page 50

background image

Chapter 3

Signal Connections

© National Instruments Corporation

3-19

Lab-PC+ User Manual

Mode 1 Output Timing

The timing specifications for an output transfer in Mode 1 are as follows:

WR*

OBF*

INTR

ACK*

DATA

T1

T2

T3

T4

T5

T6

Name

Description

Minimum

Maximum

T1

WR* = 0 to INTR = 0

450

T2

WR* = 1 to output

350

T3

WR* = 1 to OBF* = 0

650

T4

ACK* = 0 to OBF* = 1

350

T5

ACK* pulse width

300

T6

ACK* = 1 to INTR = 1

350

All timing values are in nanoseconds.