Nortel Networks NN44200-300 User Manual
Page 17
Slot assignments
17
Slot definition and slot numbering
In these tables, the term slot refers to the available slot openings in the
chassis, not the PCI or ISA connectors inside the server.
Look at the server from the rear (see
"Rear panel diagram" (page 13)
). The
slots are numbered from right to left, 1 to 20. Now, look at the server from
the front. The slots are numbered from left to right.
Note: For Meridian 1 and Communication Server 1000, the first
MPB16-4 board must be installed in slot 11. You can install up to a
maximum of two MPB16-4 boards.
1002rp slot assignments
Slot
number
CallPilot-assigned
board label
a
Meridian 1*/
Communication
Server*
1000
T1/SMDI
Slot 1
BRD01
Not used
Not used
Slot 2
BRD02
Not used
Not used
Slot 3
BRD03
Not used
Not used
Slot 4
BRD04
Not used
Not used
Slot 5
BRD05
Not used
Not used
Slot 6
BRD06
Not used
Not used
Slot 7
BRD07
Reserved for COM2
I/O bracket
Reserved for COM2
I/O bracket
Slot 8
b
BRD08
Single board
computer
Single board
computer
Slot 9 (PCI Slot 1)
BRD09
Reserved for COM1
and parallel port I/O
bracket
Reserved for COM1
and parallel port I/O
bracket
Slot 10 (PCI Slot 2)
BRD10
PCI RAID controller
PCI RAID controller
Slot 11 (PCI Slot 3)
BRD11
MPB16-4 #1 or
MPB96 #1
MPB96 board #1
Slot 12 (PCI Slot 4)
BRD12
MPB16-4 #2
(optional)
D/480JCT-2T1
a. On some CallPilot Manager screens, the CallPilot-assigned board label is displayed. This label
corresponds to the slot number. For example, BRD12 refers to the board in slot 12.
b. The SBC card includes two onboard NICs (for connection to the ELAN subnet, and the Nortel
server subnet) and an onboard video card. The NIC and monitor connectors are on the SBC
faceplate.
Nortel CallPilot
1002rp Server Hardware Installation
NN44200-300
01.01
Standard
5.0
23 February 2007
Copyright © 2007, Nortel Networks
Nortel Networks Confidential
.