Environmental specifications – Nortel Networks NN44200-300 User Manual
Page 12
12
Chapter 2 1002rp server description
Environmental specifications
Environmental condition
Specification
Operating temperature
10
C to 35
C (50
F to 95
F) Maximum
rate of change must not exceed 10
C
(50
F) per hour.
Non-operating (storage) temperature
-40
C to 70
C (-40
F to 158
F)
Non-operating humidity
95%, non-condensing at 30
C (86
F)
Altitude
1829 m (6000 ft)
Electrostatic discharge
15 kV or more
Acoustic noise
50 dBA in a typical office ambient
temperature (18
C to 25
C [64.4
F to
77
F])
Operating shock
No errors with a half sine wave shock
of 2G (with 1 millisecond duration)
Handling drop
Operational after a free fall from 450
mm to 600 mm (18 in. to 24 in.)
(depending on weight)
Front panel features (front view without the front bezel)
The front view of the 1002rp server chassis shows redundant dual fans to
the left and the right of the status panel. The left drive bay holds six SCSI
hard drives with hot-pluggable carriers. The media drive bay, located to the
right, houses the CD-ROM, tape drive, and floppy disk drive.
Nortel CallPilot
1002rp Server Hardware Installation
NN44200-300
01.01
Standard
5.0
23 February 2007
Copyright © 2007, Nortel Networks
Nortel Networks Confidential
.