Connecting to the power source, Connecting to the power source -18 – Polycom DOC2238A User Manual
Page 38
Chapter 2 - Hardware Installation
2-18
Connecting to the power source
You can connect to an AC Inlet power supply at your site. It is important to
follow these steps.
The following restrictions apply to the conductors and connectors that may be
used to ground the unit when rack mounted:
•
When using bare conductors, they must be coated with an appropriate
antioxidant compound before crimp connections are made. Tinned,
solder-plated or silver-plated connectors do not have to be prepared in
this manner.
•
The same bolt assemblies should not secure multiple connectors.
•
Listed fastening hardware must be compatible with the materials being
joined and must be preclude loosening, deterioration and electrochemical
corrosion of the hardware and joint materials.
To connect to the AC Inlet:
1.
Make sure the power switch is OFF. Insert the power cable into the
power connector on the rear panel of the MGC+100 unit.
2.
Insert the power cable into the power source socket.
3.
Turn on the power by pressing on the power switch located on the rear
panel of the MGC+100 unit.
AC Inlet
Main Switch