Configuring the System Clock Settings

43

T1/E1 DACS Administrators’ Reference Guide

6 • Clocking

netref-1(101)—N/A

netref-2(102)—N/A

internal(200)— The internal free-running oscillator is the clock source.

external(300)—The external clock source connected to the 3-position terminal block on the rear of the
2604 DACS is the clock source

Fallback Reference (daxClockFallbackRef)

The fallback reference enables the configuration of a back-up clock reference should the main reference fail.
The

Main Reference

and

Fallback Reference

parameters have the same selections for system clock. Make sure

you choose different clock sources for the Main Reference and Fallback Reference. The fallback reference set-
tings are the same as those described in section “Main Reference (daxClockMainRef )” on page 42.

Clock Status (daxClockFailure)

The clock status indicates alarm conditions relating to the system clock. If there are no alarms, the Clocking
page will indicate No Alarm (see figure 15 on page 42). If an alarm condition exists, an Alarms Present message
will be displayed along with one of the following failure descriptions.

no-failures(0)—No alarms present

main-ref-fail(1)—The main clock reference has failed

fallback-ref-fail(2)—The fall back clock reference has failed