Modify Alarms—Configuring alarm severity levels

35

T1/E1 DACS Administrators’ Reference Guide

4 • Alarms

Temperature Threshold

An alarm message is generated when the internal box temperature exceeds this threshold value (degrees Cel-
sius). You can change the threshold temperature, but we recommend that you use the factory default.

Modify Alarms—Configuring alarm severity levels

Clicking on

Modify Alarms

window (see figure 12) displays a table listing each individual alarm. From this

page you can configure the severity for each alarm (such as major, minor, major self-clearing, and minor self-
clearing). Each alarm can be disabled as appropriate for your application.

Figure 12. Modify Alarms settings window

There are 83 alarms that can be independently configured to generate alarm messages. Each alarm item can be
set for one of the following severity levels:

Ignore(0)—Do not generate an alarm.

Minor(1)—Generate a minor alarm that will not reset until the administrator manually clears it.

Major(2)—Generate a major alarm that will not reset until the administrator manually clears it.