beautypg.com

Lc2h, Explanation of operation, Backlight type – Panasonic LC2H User Manual

Page 8

background image

LC2H

2. Backlight type

Notes) 1. Do not reverse the polarities when connecting the DC voltage for the backlight.

2. 2 and 4. (The input and reset circuits are functionally insulated.)
3. When using transistor (Tr) input, use the right as a guide. (Collector withstand voltage Q 50 V, leakage current < 1 µA)
4. Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input

terminal, can cause damage to the internal elements.

Explanation of operation

Voltage input type

Backlight connection

Contact input

Transistor input

NPN transistor

PNP transistor

Reset

input

Count

input

1

2

3

4

5

6

0V

0V

Reset

input

Count

input

1

2

3

4

+V

+V

5

6

1

2

3

4

5

6

Reset

input

Count

input

+V

+V

1

2

3

4

Green

Red

24V DC

24V DC

5

6

1

2

3

4

5

6

1. Counting takes place when the count
input signal is ON.
2. Counting resumes again when the
count value reaches 99999999 (full scale
value) and then returns to “0” with a new
count input.
3. No measurement takes place when a
reset is input.
1) When reset is ON, resetting takes
place and the count becomes “0”.
2) Press the front reset button when you
want to reset manually (only panel
installation type).

Note) Be aware that battery life will decrease if the

count input or reset input are left ON.

Note)

❇Count becomes “1” when the reset input is turned OFF while the count signal is being input.

Reset input

Count value

Count input

0

1

0

0

1

1

99999999