Installing a hot-swap fan assembly, Installing, Hot-swap – Lenovo RD210 User Manual

Page 96: Assembly

background image

1

Fan

tabs

6

Fan

4

2

Fan

connector

on

the

system

board

7

Fan

5

3

Fan

1

8

Fan

6

4

Fan

2

9

Fan

connector

5

Fan

3

10

Fan

(side

view)

4.

Grasp

the

orange

fan

tabs

on

both

ends

of

the

fan

and

pull

it

up

out

of

the

server.

If

you

are

removing

fans

3

and

4,

you

need

to

first

remove

the

DIMM

air

baffle

(see

“Removing

and

installing

the

DIMM

air

baffle”

on

page

48).

Attention:

To

ensure

proper

operation,

replace

a

failed

fan

as

soon

as

possible.

5.

If

you

are

instructed

to

return

the

fan,

follow

all

of

the

packaging

instructions,

and

use

any

packaging

materials

for

shipping

that

are

supplied

to

you.

Installing

a

hot-swap

fan

assembly

To

install

an

additional

hot-swap

fan,

complete

the

following

steps:

1.

Read

the

safety

information

in

“Safety”

on

page

vii

and

“Installation

guidelines”

on

page

39.

2.

Remove

the

cover

(see

“Removing

and

replacing

the

cover”

on

page

43).

3.

Touch

the

static-protective

package

that

contains

the

new

fan

to

any

unpainted

metal

surface

on

the

server.

Then,

remove

the

new

fan

from

the

package.

4.

If

you

are

replacing

a

fan,

grasp

the

orange

fan

tabs

1

on

both

ends

of

the

existing

fan

and

pull

it

up

out

of

the

server.

If

you

are

replacing

fans

3

and

4,

you

will

need

to

remove

the

DIMM

air

baffle

first

(see

“Removing

and

installing

the

DIMM

air

baffle”

on

page

48).

80

ThinkServer

RD210

Types

3795,

3796,

3818,

and

3819:

Installation

and

User

Guide