Lenovo RD210 User Manual
Page 181
Power-supply
LEDs
Power-supply
error
LED
Description
Action
AC
DC
Off
Off
Off
No
power
to
the
server,
or
a
problem
with
the
ac
power
source.
1.
Check
the
ac
power
to
the
server.
2.
Make
sure
that
the
power
cord
is
connected
to
a
functioning
power
source.
3.
Remove
one
power
supply
at
a
time.
Off
Off
On
No
power
to
the
server,
or
an
internal
power
supply
problem.
v
Make
sure
that
the
power
cord
is
connected
to
a
functioning
power
source.
v
Replace
the
power
supply.
Off
On
Off
Power
supply
problem.
Replace
the
power
supply.
Off
On
On
Power
supply
problem.
Replace
the
power
supply.
On
Off
Off
DC
source
power
problem.
1.
Reseat
the
power
supply.
2.
If
the
problem
remains,
check
the
240v
Aux
channel
error
LED
on
the
system
board
and
do
the
following:
a.
If
the
LED
is
lit,
(trained
service
technician
only)
replace
the
system
board.
b.
If
the
LED
is
not
lit,
replace
the
power
supply.
On
Off
On
Power
supply
problem.
Replace
the
power
supply.
On
On
Off
Standby
power
problem.
1.
View
the
event
log
(see
the
Hardware
Maintenance
Manual
for
information
about
error
logs).
2.
Remove
one
power
supply
at
a
time.
On
On
On
Power
supply
problem,
but
still
operational.
Replace
the
power
supply.
On
On
Flashing
System
power-on
problem.
1.
View
the
system-error
log
(see
the
Hardware
Maintenance
Manual
for
information
about
error
logs).
2.
Press
the
power-control
button
on
the
operator
information
panel.
3.
(Trained
service
technician
only)
Use
the
force-power-on
jumper
as
a
debugging
aid
(see
the
Hardware
Maintenance
Manual
to
determine
whether
the
information
panel
switch
and
cable
are
faulty).
4.
(Trained
service
technician
only)
Replace
the
microprocessor.
On
On
Off
The
power
is
good.
No
action
is
necessary.
Chapter
7.
Solving
problems
165