beautypg.com

Installing the dimm air baffle, Removing and installing a hot-swap hard disk drive, Installing – Lenovo RD210 User Manual

Page 66: Dimm, Baffle, Removing, Hot-swap, Hard, Disk, Drive

background image

Installing

the

DIMM

air

baffle

Attention:

For

proper

cooling

and

airflow,

replace

the

air

baffle

before

you

turn

on

the

server.

Operating

the

server

with

the

air

baffle

removed

might

damage

server

components.

To

install

the

DIMM

air

baffle,

complete

the

following

steps:

1.

Read

the

safety

information

in

“Safety”

on

page

vii

and

“Installation

guidelines”

on

page

39.

2.

Turn

off

the

server

and

peripheral

devices

and

disconnect

the

power

cords

and

all

external

cables,

if

necessary.

3.

Align

the

DIMM

air

baffle

over

the

DIMMs

so

that

the

baffle

pin

on

the

left

side

of

the

air

baffle

aligns

with

the

pin

hole

next

to

DIMM

connector

8

on

the

system

board

and

lower

it

into

the

server.

Removing

and

installing

a

hot-swap

hard

disk

drive

The

following

notes

describe

the

type

of

internal

drives

that

the

server

supports

and

other

information

that

you

must

consider

when

installing

a

drive.

For

a

list

of

supported

hard

disk

drives,

go

to

www.lenovo.com/thinkserver

and

click

on

the

Options

&

Software

tab.

v

Locate

the

documentation

that

comes

with

the

drive

and

follow

those

instructions

in

addition

to

the

instructions

in

this

chapter.

v

Make

sure

that

you

have

all

the

cables

and

other

equipment

that

are

specified

in

the

documentation

that

comes

with

the

drive.

v

Select

the

bay

in

which

you

want

to

install

the

drive.

v

Check

the

instructions

that

come

with

the

drive

to

determine

whether

you

have

to

set

any

switches

or

jumpers

on

the

drive.

If

you

are

installing

a

SAS

or

SATA

hard

disk

drive,

be

sure

to

set

the

SAS

or

SATA

ID

for

that

device.

v

The

server

supports

six

2.5-inch

hot-swap

SAS

or

hot-swap

SATA

hard

disk

drives.

v

All

hot-swap

drives

in

the

server

should

have

the

same

throughput

speed

rating.

Mixing

hard

disk

drives

with

different

speed

ratings

will

cause

all

drives

to

operate

at

the

lower

throughput

speed.

50

ThinkServer

RD210

Types

3795,

3796,

3818,

and

3819:

Installation

and

User

Guide

This manual is related to the following products: