Lenovo THINKSERVER 3821 User Manual
Page 70
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
SSL data in the IMM configuration
data is invalid. Clearing configuration
data region and disabling SSL+H25.
Error
There is a problem with the
certificate that has been
imported into the IMM. The
imported certificate must
contain a public key that
corresponds to the key pair
that was previously
generated through the
Generate a New Key and
Certificate Signing
Request link.
1. Make sure that the certificate
that you are importing is
correct.
2. Try to import the certificate
again.
Flash of %1 from %2 succeeded for
user %3.
(%1 = CIM_ManagedElement.
ElementName;
%2 = Web or LegacyCLI;
%3 = user ID)
Info
A user has successfully
updated one of the following
firmware components:
v
IMM main application
v
IMM boot ROM
v
Server firmware
v
Diagnostics
v
Integrated service
processor
No action; information only.
Flash of %1 from %2 failed for user
%3.
(%1 = CIM_ManagedElement.
ElementName;
%2 = Web or LegacyCLI;
%3 = user ID)
Info
An attempt to update a
firmware component from
the interface and IP address
has failed.
Try to update the firmware again.
The Chassis Event Log (CEL) on
system %1 is 75% full.
(%1 = CIM_ComputerSystem.
ElementName)
Info
The IMM event log is 75%
full. When the log is full,
older log entries are
replaced by newer ones.
To avoid losing older log entries,
save the log as a text file and
clear the log.
The Chassis Event Log (CEL) on
system %1 is 100% full.
(%1 = CIM_ComputerSystem.
ElementName)
Info
The IMM event log is full.
When the log is full, older
log entries are replaced by
newer ones.
To avoid losing older log entries,
save the log as a text file and
clear the log.
%1 Platform Watchdog Timer expired
for %2.
(%1 = OS Watchdog or Loader
Watchdog; %2 = OS Watchdog or
Loader Watchdog)
Error
A Platform Watchdog Timer
Expired event has occurred.
1. Reconfigure the watchdog
timer to a higher value.
2. Make sure that the IMM
Ethernet over USB interface
is enabled.
3. Reinstall the RNDIS or
cdc_ether device driver for
the operating system.
4. Disable the watchdog.
5. Check the integrity of the
installed operating system.
IMM Test Alert Generated by %1.
(%1 = user ID)
Info
A user has generated a test
alert from the IMM.
No action; information only.