Lenovo THINKSERVER 3821 User Manual

Page 120

background image

Table 4. DSA messages (continued)

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

v

See Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained
service technician.

Message
number

Component

Test

State

Description

Action

201-807-xxx

Memory

Memory Test

Aborted

Test aborted:
the memory
controller buffer
free request
failed.

1. Turn off and restart the system.

2. Run the test again.

3. Make sure that the server firmware is at the

latest level. The installed firmware level is shown
in the DSA log in the Firmware/VPD section for
this component. For more information, see
“Updating the firmware” on page 267.

4. Run the test again.

5. If the failure remains, go to the Lenovo Web site

for more troubleshooting information at
http://www.lenovo.com/support.

201-808-xxx

Memory

Memory Test

Aborted

Test aborted:
memory
controller
display/alter
buffer execute
error.

1. Turn off and restart the system.

2. Run the test again.

3. Make sure that the server firmware is at the

latest level. The installed firmware level is shown
in the DSA log in the Firmware/VPD section for
this component. For more information, see
“Updating the firmware” on page 267.

4. Run the test again.

5. If the failure remains, go to the Lenovo Web site

for more troubleshooting information at
http://www.lenovo.com/support.

201-809-xxx

Memory

Memory Test

Aborted

Test aborted
program error:
operation
running fast
scrub.

1. Turn off and restart the system.

2. Run the test again.

3. Make sure that the DSA code is at the latest

level.

4. Make sure that the server firmware is at the

latest level. The installed firmware level is shown
in the DSA log in the Firmware/VPD section for
this component. For more information, see
“Updating the firmware” on page 267.

5. Run the test again.

6. If the failure remains, go to the Lenovo Web site

for more troubleshooting information at
http://www.lenovo.com/support.

201-810-xxx

Memory

Memory Test

Aborted

Test stopped:
unknown error
code xxx
received in
COMMONEXIT
procedure.

1. Turn off and restart the system.

2. Run the test again.

3. Make sure that the DSA code is at the latest

level.

4. Make sure that the server firmware is at the

latest level. The installed firmware level is shown
in the DSA log in the Firmware/VPD section for
this component. For more information, see
“Updating the firmware” on page 267.

5. Run the test again.

6. If the failure remains, go to the Lenovo Web site

for more troubleshooting information at
http://www.lenovo.com/support.

112

ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual