Installing a hot-swap fan, Removing a microprocessor and heat sink – Lenovo THINKSERVER 3821 User Manual
Page 226
Installing a hot-swap fan
The server comes with three 120 mm x 38 mm hot-swap fans in the fan support
bracket at the front of the server. The following instructions can be used to install
any hot-swap fan in the server.
1
Hot-swap fan
To install a hot-swap fan, do the following:
1. Read the safety information that begins on page 5.
Attention:
Static electricity that is released to internal server components
when the server is powered on might cause the server to halt, which might
result in the loss of data. To avoid this potential problem, always use an
electrostatic-discharge wrist strap or other grounding system when you work
inside the server with the power on.
2. Touch the static-protective package that contains the hot-swap fan to any
unpainted metal surface on the server; then, remove the fan from the package.
3. Open the fan-locking handle on the replacement fan.
4. Insert the fan into the socket and close the handle to the locked position.
5. Install and lock the left-side cover (see “Installing the left-side cover” on page
Removing a microprocessor and heat sink
To remove a microprocessor, complete the following steps:
1. Read the safety information that begins on page 5.
2. Turn off the server and peripheral devices, and disconnect the power cords
and all external cables.
3. Carefully turn the server on its side so that it is lying flat, with the cover facing
up.
Attention:
Do not allow the server to fall over.
4. Unlock and remove the left-side cover (see “Removing the left-side cover” on
218
ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual