10.5

Section 10

Inspection and Reconditioning

10

A
B
C
D
E

F

G

H

Seat Angle
Insert O.D.
Guide Depth
Guide I.D.
Valve Head Diameter
Valve Face Angle
Valve Margin (Min.)
Valve Stem Diameter

Dimension

89°
36.987/37.013 mm
4 mm
7.038/7.058 mm
33.37/33.63 mm
45°
1.5 mm
6.982/7.000 mm

Intake

Exhaust

89°
32.987/33.013 mm
6.5 mm
7.038/7.058 mm
29.37/29.63 mm
45°
1.5 mm
6.970/6.988 mm

B

A

C

D

D

H

G

Exhaust Valve

E

F

A

Exhaust

Insert

Intake

Insert

F

E

G

H

B

A

Intake Valve

Figure 10-5. Valve Details.

Normal: Even after long hours of operation a valve
can be reconditioned and reused if the face and
margin are in good shape. If a valve is worn to where
the margin is less than 1/32" do not reuse it. The valve
shown was in operation for almost 1000 hours under
controlled test conditions.

Bad Condition: The valve depicted here should be
replaced. Note the warped head; margin damaged and
too narrow. These conditions could be attributed to
excessive hours or a combination of poor operating
conditions.