8.13

Section 8

Electrical System and Components

8

Delco-Remy Starters

Figure 8-13. Removing Solenoid Screws.

Figure 8-14. Solenoid Removed from Starter.

3. Lift and unhook the plunger assembly from the

drive lever. Remove the gasket from the recess in
the housing. See Figure 8-15.

Figure 8-15. Removing Plunger.

4. Remove the two thru (larger) bolts. See

Figure 8-16.

Figure 8-16. Removing Thru Bolts.

Figure 8-12.

Starter Disassembly

1. Remove the hex. nut and disconnect the positive

(+) brush lead/bracket from the solenoid terminal.

2. Remove the three screws securing the solenoid

to the starter. Remove the solenoid and plunger
spring from the drive end cap. See Figure 8-13
and 8-14.

This manual is related to the following products: