9.15

Section 9

Disassembly

9

Figure 9-56. Removing Dipstick Tube Assembly.

Remove Oil Sentry

(If So Equipped)

1. Remove the Oil Sentry

switch, from the breather

cover. See Figure 9-57.

Figure 9-57. Removing Oil Sentry

Switch.

Remove Breather Cover

1. Remove the four hex. flange screws securing the

breather cover to the crankcase. See Figure 9-58.

2. Carefully pry under the protruding edge of the

breather cover with a screwdriver to separate the
cover. See Figure 9-59. Do not pry on the sealing
surfaces as it could cause damage resulting in
leaks.

Figure 9-59. Prying Off Breather Cover.

3. Remove the cover and the gasket. See

Figure 9-60.

Figure 9-58. Removing Breather Cover Screws.

Figure 9-60. Removing Breather Cover and Gasket.