9.20

Section 9
Disassembly

2. Carefully remove the connecting rod and piston

assembly from the cylinder bore. See Figure 9-78.

NOTE: The cylinders are numbered on the

crankcase. Use the numbers to mark
each end cap, connecting rod, and piston
for reassembly. Do not mix end caps and
connecting rods.

Figure 9-78. Removing Connecting Rod and Piston
Assembly.

3. Repeat the above procedure for the other

connecting rod and piston assembly.

Remove Crankshaft

1. Carefully pull the crankshaft out of the crankcase.

See Figure 9-79.

Figure 9-79. Removing Crankshaft.