4.4

Section 4
Air Cleaner and Air Intake System

4. Disconnect the breather hose from the air

cleaner base.

Figure 4-9. Base Plate Removal on Standard Type.

Fuel Pump
Vacuum Line

Breather Hose

5. Slide the clamp and air cleaner base off the stud.

6. Reverse procedure to reassemble components.

Torque the hex. flange nuts to 9.9 N·m (88 in. lb.).

Radiator Cleaning
Every time the upper blower housing assembly is
removed to check or service the air cleaner, the
condition of the radiators should also be checked. If
the cleaning is necessary, follow the instructions in
Section 7 Cooling System, found on page 7.2, "Cooling
System Maintenance and Service."