beautypg.com

Kohler Aegis TP-2509 User Manual

Page 64

background image

8.14

Section 8
Electrical System and Components

Figure 8-21. Retaining Ring Detail.

5. Remove the commutator end plate assembly,

containing the brush holder, brushes, springs, and
locking caps. Remove the thrust washer from
inside the commutator end. See Figure 8-17.

Figure 8-17. Removing Commutator End Plate
Assembly.

6. Remove the frame from the armature and drive

end cap. See Figure 8-18.

Figure 8-18. Starter Frame Removed.

7. Remove the drive lever pivot bushing and backing

plate from the end cap. See Figure 8-19.

Figure 8-19.

8. Take out the drive lever and pull the armature out

from the drive end cap. See Figure 8-20.

9. Remove the thrust washer from the armature

shaft. See Figure 8-20.

Figure 8-20. Armature and Lever Removed.

10. Push the stop collar down to expose the retaining

ring. See Figure 8-21.

This manual is related to the following products: