beautypg.com

Kohler Aegis TP-2509 User Manual

Page 38

background image

5.12

Section 5
Fuel System and Governor

Throttle Control Cable

Choke Control Cable

Kill Switch
Adjusting Screw

Dual Control High Idle
Lever Stop Screw
"Do Not Remove"

High Idle
Adjusting Screw

High Idle
Control Lever

Choke Control
Cable

Throttle Control
Cable

Z Bend

Choke Linkage

Throttle
Control
Lever #2

Kill
Switch

Choke Control
Lever #1

Left Side Pull

Right Side Pull

High Idle RPM Speed Adjustment (See Figure 5-8.)

1. With the engine running, move the throttle control

to fast. Use a tachometer to check the RPM
speed.

2. Loosen the lock nut on the high idle adjusting

screw. Turn screw outward to decrease, or inward
to increase RPM speed. Check RPM with a
tachometer.

3. When the desired RPM speed is obtained,

retighten the lock nut.

NOTE: Upon establishing the high idle RPM speed,

check for a gap between the high idle control
and the choke control. The gap may be
greater, but no less than .5 mm (.02 in).

Figure 5-8. Governor Control Connections.

This manual is related to the following products: