9.3

Section 9

Disassembly

9

Figure 9-6. Separating Screen from Housing.

Remove Muffler

1. Remove the muffler or exhaust system and

attaching hardware from the engine. See Figure 9-7.

Figure 9-7. Removing Muffler.

Drain Cooling System

1. Make sure the engine is cool. Slowly remove the

radiator cap. See Figure 9-8.

Figure 9-8. Removing Radiator Cap.

2. Carefully remove the coolant drain plugs in the

lower side of both cylinder heads. See Figure 9-9.
Drain the coolant into a suitable container. Early
production units contained steel plugs, remove
only when the cylinders are cool. Replace with
brass (soft) plugs on reassembly, Kohler Part No.
66 139 01-S.

Figure 9-9. Location of Coolant Drain Plugs.

Remove Fuel Pump

1. Disconnect the pulse (vacuum) line from the

crankcase fitting. See Figure 9-10.

Figure 9-10. Disconnecting Pulse Line from Fitting.