beautypg.com

Kohler Aegis TP-2509 User Manual

Page 77

background image

9.5

Section 9

Disassembly

9

Figure 9-17. Loosening Governor Lever Clamp Nut.

3. Remove the four hex. flange screws securing the

throttle control bracket to the cylinder heads. See
Figure 9-18.

Remove Control Bracket Assembly and
External Governor Lever

1. Disconnect any remote throttle and/or choke

control cables connected to the throttle control
bracket.

2. Loosen the hex. flange nut on the clamp screw

securing the governor lever to the cross shaft.
See Figure 9-17.

Remove Carburetor

1. Disconnect the fuel solenoid leads (most models)

from the wiring harness.

2. Disconnect the dampening spring and throttle

linkage from the governor arm. Remove the black
bushing, and clip it back onto the linkage, so it
does not get lost. See Figure 9-15.

Figure 9-15. Removing Throttle Linkage,
Dampening Spring, and Black Bushing.

3. Gently lift up on the lower blower housing, directly

above the carburetor, and slide the carburetor
outward on the studs. See Figure 9-16.

Figure 9-16. Lifting Edge of Lower Housing/
Removing Carburetor.

4. Disconnect the choke linkage from the carburetor,

then remove the carburetor and gaskets from the
studs.

Figure 9-18. Removing the Four Screws from Main
Throttle Bracket.

This manual is related to the following products: