beautypg.com

Kohler Aegis TP-2509 User Manual

Page 81

background image

9.9

Section 9

Disassembly

9

Figure 9-31. Removing Center Mounting Nut.

2. Cut the metal tie strap from around the lower

hose/tube assembly, secured to the blower
housing. See Figure 9-32.

Remove Radiators and Cooling System

1. Remove the hex. nut from the center mounting

stud, located between the two radiators and
through the main support bracket. See Figure 9-31.

Figure 9-32. Cutting Tie Strap off.

Figure 9-33. Rear Bracket/Clamp.

Figure 9-34. Unseating By-pass Hose.

3. Remove the two screws attaching the rear

support bracket and half clamp to the crankcase,
on the oil filter side. See Figure 9-33.

Figure 9-35. Moving Hose Clamp with Special Pliers.

5. Unseat the clamps and separate the hose

connections at the outlet of the thermostat
housing and the inlet of the water pump. See
Figures 9-35, 9-36. Remove the tubular spacer
from the underside of center mount, or the
mounting stud in intake manifold. See step 1.

4. Pull the by-pass hose out of the retaining clip

beneath the main support bracket. See Figure 9-34.