Field Diagnostic Test
During the Field Diagnostic Test the terminal displays and updates this screen:
Figure A-10. The Field Diagnostic Test
describes the field contents. The reports wrap so that the last five message reports
are visible. If you selected non-stop mode during setup, and the Ping Test or Error count fields
overflow, then the first detail line shows the most significant digits of the count, prefixed with
an asterisk.
Table A-5. Field Diagnostic Test Field Details
Field
Description
Association Indicator
A — the radio is associating with an AP.
U — the radio is not associating with an AP.
Ping Test Count
Displays the number of each test as it runs.
Error Count
Displays the cumulative number of errors that have occurred.
Retry Count
The retry count for this message.
Timer
The round-trip time in milliseconds, or an indication of error type,
if there was an error.
Access Point ID
The ID of the AP with which the terminal is associating.
AP PING TEST
A Cnt
Err
Rty
ms AP
56
0
0
165
18
57 0
0
55
18
58
1
1
TMO
18
59
1
0
220
18
60 1
0
58
18
Press ‘Q’ to Quit