Symbol Technologies VRC 6940 User Manual
Page 56
6-11
Troubleshooting
10. If the VRC 6940 has EMS, use the arrow keys to specify the range to transfer. This
prompt only appears if EMS is installed. Then press ENTER.
Figure 6-7. Selecting a Range of EMS to Transfer
11. The terminal displays the ranges you selected. Verify that they are correct.
shows an example of what you might see. If the values are correct, press ENTER.
If the values are not correct, press CLEAR to clear the fields, then select new values.
Figure 6-8. Verifying Memory Transfer Settings
12. Next, the VRC 6940 prompts you to set communications parameters. Use UP or
DOWN arrows to select communications settings. The defaults are 9600 bps, 7 data
bits and odd parity. Xon/xoff flow control may be necessary at 38400 bps. Select the
parameters so that they match those used by RCVHEX on the Host PC.
EMS
Use arrow keys
Start End
RAM 0000 9FFF
NVM B135 DFFF
EMS None
Correct?