Example B–1 illustrates an error-free BDLC sequence between the host
computer and the adapter. This sequence shows how information is efficiently
transferred, since acknowledgements are part of the control subfield and does
not require a separate transmission.

Example B–1

BDLC Error-free Sequence

Host Computer

(1) SNRM

UA

(2) I–Frame, N(S)=0, N(R)=0, P

RR, N(R)=1, F

(3) I–Frame, N(S)=1, N(R)=0, P

I–Frame, N(S)=0, N(R)=2, F

(4) RR, N(R)=1, P

RR, N(R)=2, F

(5) RR, N(R)=1, P

I–Frame, N(S)=1, N(R)=2, F

(6) DISC

UA

... 7 second delay ...

(7) RR, N(R)=0, P

DM

UNILINK Host