Æ qos l2/l3, D (æ qos l2 – Siemens HiPath 4000 User Manual
Page 75
Description of functions
Alphabetical Reference
75
QCU Home Address
•
Enter the
Æ IP address of the QCU-Server on which the QoS-Data have
to be reported.
•
Standard value
QCU Standby Address
•
Only available when using a second communication platform.
•
Enter the
Æ IP address of the QCU-Server on which the QoS-Data have
to be reported during emergency mode.
QDC Server
•
Enter the
Æ Port-Number for communication with the QDC-Server.
•
Standard value
QoS L2/L3
•
The settings relate to the
Æ Layer 2 and Æ Layer 3 areas of the
Æ QoS, that regulate the prioritisation of the transferred data.
•
Æ VLAN Method and the Æ Default VLAN ID can be
Æ L2/L3 Voice/Signalling can be changed.
•
The activation of Layer 2 and / or Layer 3 support is meaningful only if
the used
Æ Switch can interpret this information (e.g., "Layer 2
Switch").
•
Standard value
QoS Protocol Version
•
The Version Number gives information regarding the actuality of the
QoS report file (read only).
RAM Test
•
Here you can test the
Æ RAM memory of your optiPoint 410/420.
•
The results are displayed after the test is over.
Report Interval
•
Time interval (in sec.) in reports are sent.
•
For each Report Interval a QoS report will be sent if the
Mode was set accordingly.
•
Valid values: 10 ... 3600.
•
Standard value