Binary encoded ASCII table

Technical data

101

Technical data

optiPoint 410/420 economy/economy plus/standard/advance

Protocols

H.323, H.225, H.245,
TCP/IP, FTP, DHCP, SNTP, SRTP/SRTCP

[[1]]

Gatekeeper routed and direct routed call model

[1] Only for optiPoint 410/420 economy plus/standard/advance with software version 5.x or

higher on HiPath 3000/5000 (version 6.0 or higher) and HiPath 4000 (version 3.0 or higher).

Voice algorithms

G.711 (64 kbit/s),
G.723.1 (6,4 kbit/s)
Room echo compensation

Interfaces

IEEE 802.3 Fast Ethernet (10/100 Mbit/s)
2 x RJ 45 TP

Pin assignment:
LAN receptacle

Pin 1 TX +
Pin 2 TX -
Pin 3 RX +
Pin 4 -- (DC+)
Pin 5 -- (DC+)
Pin 6 RX -
Pin 7 -- (DC-)
Pin 8 -- (DC-)

Handset receptacle

Pin 1 microphone -
Pin 2 receiver cap +
Pin 3 receiver cap -
Pin 4 microphone +

Power supply
unit receptacle

Pin 1 V -
Pin 2 --
Pin 3 --
Pin 4 --
Pin 5 --
Pin 6 V +

Power supply
(external plug-in
power supply unit)

EU-variant, grounding plug (230 V, 50 Hz)
UK-variant (230 V, 50 Hz)
US-variant (110 V, 60 Hz)