Æ ldap template filename – Siemens HiPath 4000 User Manual
Page 72
Alphabetical Reference
Description of functions
72
LDAP Template Filename
•
Only configurable on optiPoint 410/420 standard/advance and only re-
quired if a display module or application module will be used.
•
If an
Æ LDAP server is used, enter the name of the LDAP template file
that is used in connection with this server.
•
The file must exist in a defined directory on the
•
Standard name
•
LED Test
•
Conduct this test to check the function of the
Æ LED in the
optiPoint 410/420 zu prüfen.
•
All the LEDs blink during the test.
Line Status
•
Activate the display to view the functions and values used to run the
Æ LAN connections in the optiPoint 410/420.
•
Bit rate, activity, half / full duplex, as well as the status of the used net-
work or the manual setting in the optiPoint 410/420.
•
The display takes place through the
Æ LEDs of the right row:
•
The status monitor remains active even during the normal operation of
the optiPoint 410/420. However, it does not affect the operation of the
function keys.
Port
[
[1]]
[1] See
Function
LEDs on optiPoint 410/420 (right row)
PC
Activity
LED1
Not Active
Active
Speed
LED2
10 Mbit/s
100 Mbit/s
Duplex
LED3
Half-Duplex
Full-Duplex
(no function)
LED4
-
-
LAN
Activity
LED5
Not Active
Active
Speed
LED6
10 Mbit/s
100 Mbit/s
Duplex
LED7
Half-Duplex
Full-Duplex
(no function)
LED8
-
-