Seagate Fibre Channel Interface User Manual
Page 84

70
Fibre Channel Interface Manual, Rev. D
Field definitions (listed alphabetically)
Service Options
The following class 3 service parameters are sent by the drive.
Table 36:
Class 3 Service Parameters
Bit
Byte
7
6
5
4
3
2
1
0
0
Class
Valid
Intermix
Mode
Stacked Connect
Request
Sequence
Delivery
Dedicated
Simplex
Camp-on
Buffered
Class 1
Service Options
1
Priority
0
0
0
0
0
0
0
Reserved
2
Reserved
3
4
5
6
7
8
9
10
11
12
13
14
15
Table 37:
Service Option Class 3 fields
Option
Drive
Support (FLOGI)
Requirement (FLOGI ACC)
Class Valid
1
Must = 1
Intermix Mode
0, not applicable or valid for class 3.
Not checked
Stacked Connect Request
00, not applicable or valid for class 3.
Not checked
Sequence Delivery
1
Must = 1
Dedicated Simplex
0, Not applicable or valid for class 3
Not checked
Camp-on
0, not applicable or valid for class 3.
Not checked
Buffered Class 1
0, not applicable or valid for class 3
Not checked
Priority
0, not applicable or valid for class 3
Not checked
Table