Seagate Fibre Channel Interface User Manual
Page 31

Fibre Channel Interface Manual, Rev. D
17
Seagate disc drives use only those listed in bold type (Seagate Fibre Channel disc drives are Class 3 devices
and use only Class 3 delimiters).
Notes.
1. EOF primitives come in two forms—one is used when the beginning running disparity is positive and the
other is used if the beginning running disparity is negative. Regardless of which form is used, each EOF
delimiter is defined so that negative current running disparity results after processing the final (rightmost)
character of the ordered set.
2. Ordered sets associated with SOF delimiters, primitive signals, and primitive sequences are always trans-
mitted with negative beginning running disparity. As a result, primitive signals, primitive sequences, and
SOF delimiters are only defined for the negative beginning running disparity case.
3. Frames that end with any other EOF type are discarded by the drive.
Table 4:
Frame delimiters
Delimiter function
Delimiter
Beginning
running
disparity
Ordered set (FC-1)
Ordered set (hex)
SOF Connect Class 1
SOFc1
Negative
K28.5 D21.5 D23.0 D23.0
BC B5 17 17
SOF Initiate Class 1
SOFi1
Negative
K28.5 D21.5 D23.2 D23.2
BC B5 57 57
SOF Normal Class 1
SOFn1
Negative
K28.5 D21.5 D23.1 D23.1
BC B5 37 37
SOF Initiate Class 2
SOFi2
Negative
K28.5 D21.5 D21.2 D21.2
BC B5 55 55
SOF Normal Class 2
SOFn2
Negative
K28.5 D21.5 D21.1 D21.1
BC B5 35 35
SOF Initiate Class 3
SOFi3
Negative
K28.5 D21.5 D22.2 D22.2
BC B5 56 56
SOF Normal Class 3
SOFn3
Negative
K28.5 D21.5 D22.1 D22.1
BC B5 36 36
SOF Initialize Loop
SOFil
Negative
K28.5 D21.5 D22.2 D22.2
BC B5 56 56
SOF Activate Class 4
SOFc4
Negative
K28.5 D21.5 D25.0 D25.0
BC B5 19 19
SOF Initiate Class 4
SOFi4
Negative
K28.5 D21.5 D25.2 D25.2
BC B5 59 59
SOF Normal Class 4
SOFn4
Negative
K28.5 D21.5 D25.1 D25.1
BC B5 39 39
SOF Fabric
SOFf
Negative
K28.5 D21.5 D24.2 D24.2
BC B5 58 58
EOF Terminate
EOFt
Negative
Positive
K28.5 D21.4 D21.3 D21.3
K28.5 D21.5 D21.3 D21.3
BC 95 75 75
BC B5 75 75
EOF Disconnect-
Terminate
EOFdt
Negative
Positive
K28.5 D21.4 D21.4 D21.4
K28.5 D21.5 D21.4 D21.4
BC 95 95 95
BC B5 95 95
EOF Abort
EOFa
Negative
Positive
K28.5 D21.4 D21.7 D21.7
K28.5 D21.5 D21.7 D21.7
BC 95 F5 F5
BC B5 F5 F5
EOF Normal
EOFn
Negative
Positive
K28.5 D21.4 D21.6 D21.6
K28.5 D21.5 D21.6 D21.6
BC 95 D5 D5
BC B5 D5 D5
EOF Disconnect-
Terminate-Invalid
EOFdti
Negative
Positive
K28.5 D10.4 D21.4 D21.4
K28.5 D10.5 D21.4 D21.4
BC 8A 95 95
BC AA 95 95
EOF Normal-Invalid
EOFni
Negative
Positive
K28.5 D10.4 D21.6 D21.6
K28.5 D10.5 D21.6 D21.6
BC 8A D5 D5
BC AA D5 D5