Configure the adapter with the following command – Sun Microsystems X1150A User Manual
Page 44
22
Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003
2. If the status of the slot is not “empty” or “disconnected”, type:
where the sysctrl# =
0
for the Enterprise 10000 and slot#= the slot available for the
adapter. For example, if you were installing the adapter into slot #3 on an Enterprise
10000, you would type the following:
3. Physically insert the adapter into the slot and look for an acknowledgement on
the console, such as, “name
board inserted into slot3
.”
After the adapter is inserted, the states and conditions should become:
Any other states or conditions should be considered an error.
4. Connect any peripheral cables and interface modules to the adapter.
5. Connect the cables to the card and to an Ethernet network.
6. Configure the adapter with the following command:
This command should both connect and configure the receptacle. Verify with the
cfgadm
command.
The states and conditions for a connected and configured attachment point should
be:
# cfgadm -c disconnect
sysctrl#:slot#
# cfgadm -c disconnect sysctrl0:3
Receptacle state—Disconnected
Occupant state—Unconfigured
Condition—Unknown
# cfgadm -v -c configure
sysctrl#:slot#
Receptacle state—Connected
Occupant state—Configured
Condition—OK