beautypg.com

Set the adv-autoneg-cap parameter to 0, Failure to configure gigaswift ethernet instance, Non-specific issues – Sun Microsystems X1150A User Manual

Page 102

background image

78

Sun GigaSwift Ethernet Adapter Installation and User’s Guide • February 2003

2. Set the

adv-autoneg-cap

parameter to

0

.

Note –

See Chapter 4 for the default values of these parameters and for instructions

on how to set these parameters.

Failure to Configure GigaSwift Ethernet Instance

If your machine fails to configure a GigaSwift Ethernet instance, yet

prtconf

indicates the adapter is present, the problem may be due to residue adapter
instances in the

path_to_inst

file.

To solve this problem, open the

path_to_inst

file for editing and remove the lines

containing

ce

device path.

Reboot the machine and try to configure it again.

Non-Specific Issues

TABLE B-1

describes the problems you may encounter in using the GigaSwift Ethernet

adapter as well as a solution for them:

TABLE B-1

Troubleshooting the GigaSwift Ethernet Adapter

Problem

Description

Solution

prtdiag

does not

recognize the NIC in
slot 0.

If a PCI I/O board of an UltraSPARC III system is filled
with network adapters with an internal bridge (for
example, GigaSwift Ethernet or Quad FastEthernet),

prtdiag

displays the card on slot 0. Although the card

in slot 1 is not recognized by

prtdiag

, the card is fully

operational and appears in the

/etc/path_to_inst

file.

Use

prtconf -pv

instead of

prtdiag

VLAN appears to
accept VID 0 as end
user input.

ce000000

,

ce00000,

or

ce0000

configured as VID

0

is actually the regular

ce0

interface not VID

0

of the

ce0

interface. VID

0

is not supported as an end user

device.

This is normal behavior.