7 sip connection and communication, 1 response timer, 2 connectivity check – Siemens HIPATH 20 User Manual
Page 79: 7 sip connection and communication -38
administration.fm
A31003-O1010-M100-9-76A9, 05/05/2008
HiPath 8000 - OpenStage Family, Administration Manual
3-37
Administration
System Settings
3.5.7
SIP Connection and Communication
3.5.7.1
Response Timer
The Response timer is started whenever the phone sends a new message to the SIP server.
If the timer expires before the phone gets a response from the SIP server, the phone assumes
that the server had died and then attempts to contact the backup server, if configured. If there
is no backup server configured, the phone just tidies up internally.
The data is given in milliseconds. The default value is 32 000; for the HiPath 8000, the recom-
mended setting is 3.7 seconds (3700 ms).
Administration via WBM
System > SIP interface
Administration via Local Phone
3.5.7.2
Connectivity Check
A regular check ensures that the TLS link is active. When the Connectivity check timer is set
to a non-zero value, test messages will be sent at the defined interval. If the link is found to be
dead, the phone searches for another links.
Administration via WBM
System > SIP interface
|
--- Administration
|
--- System
|
--- SIP Interface
|
--- Response timer (ms)